How to judge the normal operation of air shower
Author: ComeFrom: Date:2016/9/26 13:45:35 Hits:1492
The use of air shower business sometimes encounter air shower failure, generally have the following questions:
First, the power switch. Usually there are three places where the wind leaching room can cut off the power:
1, the air shower outside the box power switch;
2, the air shower indoor control panel;
3, air shower on both sides of the outer box body (where the power switch to prevent emergency power cut off, effectively improve the staff's personal safety). When the power light is blocked, do not prevent re-check the power of the three air shower room.
Second, the air shower room fan does not work. When the air shower does not work, the first time to check the air shower outside the box emergency switch is cut off, such as determined cut off, hand gently, to the right side of the spin to let go.
Third, the air shower fan reversing or windshield room wind speed is very small, be sure to check the 380V three-phase four-wire line is reversed, the general wind leaching room manufacturer factory installation will have someone's electrical connection line; Then the air shower room line source, the light will cause the air shower fan does not work or reverse the air shower wind speed decreases, the weight will burn the entire air shower board; as air shower manufacturers, we recommend The use of air shower business enterprises do not lightly to replace the wiring, production needs to determine if you want to move, please consult the air shower manufacturers to solve.
Fourth, the air shower does not shower, in addition to the above three points, the need to check the air shower inside the emergency stop button is pressed, such as the emergency stop button for the color, the air shower will not shower; To re-press the emergency stop button can work.
Fifth, the air shower can not automatically sense blowing shower, please check the air shower indoor light-sensing system at the lower right corner of the box to see whether the light-sensing device is installed correctly, such as light perception on both sides of the relative light perception and normal, you can automatically sense blowing Shower.
Six, air shower Use a period of time when the wind speed is very low, please check the wind leaching room early, high efficiency filter is too much dust, so please replace the filter. (Air shower early effect filter is generally replaced within 1-6 months, air shower efficient filter is generally 6-12 months to replace a).